MTLT
Manifolds for industrial gas supply systems - LOW FLOW RANGE - MTLT - three sources with manual change over system
Manifold used in supply systems for industrial, inert, flammable, oxidizing gases and gas mixtures. Not usable for corrosive or toxic gases and gas mixtures.
SPECIAL FEATURES
- Switching between three sources by manual valve actuation
- Metal diaphragm for valves and regulators
- Compact design
- Valves - designed and approved in accordance with relevant sections of EN ISO 10297 (including O2 - ignition test for main shut off valve)
- Regulator - designed and approved regarding ISO 7291 (including O2 - ignition test)
- Electrostatic chargeability test
- fulfill requirements according DIN EN ISO 80079-36; IEC TS 60079-32-1 and German TRGS 727
- usable in EX-areas zones 1 and 2 for gases with explosion risk group l; llA; llB; llC
MOUNTING PANEL
- Consists of two parts (plates)
- Easy installation of ground plate (without weight of manifold)
- Simply mount front plate and fix with one screw only
- Front plate cutout for in-field gauge replacement
- Option to secure arrestor cable of HOSES with hook on ground plate
- Grounding bolt on back plate
TECHNICAL DATA - MANIFOLD
Max. inlet pressure: | 300 bar |
Delivery pressures: | 10 bar, 20 bar, 40 bar, 100 bar |
Nominal flow: | 20 m3/h |
Working temperatures: | -20°C to +60°C |
Inlet/outlet ports: | NPT ¼" female |
Leakage rate seat: | less than 50 cm3/h (23°C; 1,013 bar absolut) Compressed Air |
Leakage rate outside: | less than 10 cm3/h (23°C; 1,013 bar absolut) Compressed Air |
Materials gas wetted parts: | Brass |